Call us: 0870 300 3388 (UK) +44 1908 272770 (Int)
Email: pcisales@pcicase.co.uk
>Total Max Power:500 W
>Input Voltage:85 V to 264 V
>Outputs:Single-output
>Dimension (D x W x H): 322 x 54.5 x 40 mm
322 x 50 x 40 mm
GENERAL SPECIFICATIONS
Hold-up time 18ms @ 75% Load
Efficiency at least above 94% @ 50% Load
MTBF 50,000 hours at 100% load and 50 degree C
ENVIRONMENTAL SPECIFICATIONS
Temperature 0 to 50 degree C Operating
Altitude 10,000 feet Operating
Relative humidity 20% to 90% RH Operating
INPUT SPECIFICATIONS
Input voltage 85- 264 V
Input frequency 47 - 63 Hz
Input current 11.0 - 3.0 A
OUTPUT SPECIFICATIONS
Voltage Regulation Max Load Ripple & Noise
+12V ± 5% 42A 120mV
+5Vsb ± 5% 4A 50mV
Note:
1. The total output power can not exceed 500W continuously for 90 to 264VAC input
2. During load changes from minimum to maximum or maximum to minimum
or no load the unit must not shut down or damage
3.Please call for PDB(Power Distrubution Board) price & Model relative to your application, refer to attached Building Block instruction.
Power Supply Datasheet | Datasheet |
CPR-5011-2M1LF + CPR-5011-2M2LF Datasheet.pdf
|
|
Power Supply Technical Drawing | Drawing |
CPR-5011-2M1LF + CPR-5011-2M2LF Drawing.pdf
|
|
Power Supply Test Report | Test Report |
CPR-5011-2M1LF + CPR-5011-2M2LF Test Report.pdf
|
|
CompuWare Building Blocks | Building Block Application |
Compuware Building Block Application.pdf
|