Voltage | AC input 90 - 264Vac DC input 180 - 300Vdc |
Frequency | 47 - 63Hz |
Current | 100 - 240Vac / 11.4 - 3.9A 200 - 240Vdc / 5.6 - 3.4A |
Voltage | +12V | +5Vsb |
Regulation | ±5% | ±5% |
Max Load | 75A(100-240Vac/ 200-240Vdc) | 4.0A |
Ripple & Noise | 120mVp-p |
50mVp-p |
Hold-up time | 11 ms @ 75% load |
Efficiency | At least 94% @ 50% load |
MTBF | 400,000 hours at 30°C |
Temperature | Operating: 0 to 55°C Non-operating: -40 to 70°C ambient |
Altitude | Operating: 16,500 feet (5,000 meters) Non-operating: 35,000 feet (10,580 meters) |
Relative humidity | Operating: 5% to 90% RH, non-condensing Non-operating: 5% to 95% RH, non-condensing |
Power Supply Datasheet | |
|
Power Distribution Board : CPR-1621-2HS